Motion Artifact Removal from Photoplethysmographic Signals Using Constrained ICA and Adaptive Filtering
PPGsignal processingICAadaptive filteringbiomedical engineering

Motion Artifact Removal from Photoplethysmographic Signals Using Constrained ICA and Adaptive Filtering

2025Independent / Research CollaborationRole: Algorithm Development and Software ImplementationProgramme: Biomedical Signal Processing

Project description

This project focused on the removal of motion artifacts from long-duration photoplethysmographic (PPG) signals, a critical challenge in wearable and ambulatory physiological monitoring.

PPG signals, commonly used to estimate heart rate and heart rate variability, are highly susceptible to motion-induced noise, which often overlaps spectrally with the physiological signal of interest. The objective was to recover clean pulse waveforms from 12-hour continuous recordings sampled at 200 Hz, including dual-channel measurements (distal and proximal).

The implemented solution followed the methodology proposed by Peng et al. (2014), combining temporally constrained Independent Component Analysis (cICA) with an adaptive Least Mean Squares (LMS) filter to achieve robust signal separation and denoising.

Methodology

The processing pipeline included:

Segmentation: Division of 12-hour recordings into 1-minute windows (12,000 samples each) to enable localized artifact handling Preprocessing: Application of a low-pass FIR filter (cutoff at 4 Hz) and DC component removal to isolate relevant physiological frequencies Reference Signal Construction: Estimation of heart rate using autocorrelation and peak detection, followed by generation of a synthetic pulse train used as a constraint Constrained ICA (cICA): Separation of independent components using the reference signal to guide extraction of the physiological pulse while isolating motion artifacts Adaptive Filtering (LMS): Final refinement of the signal by adaptively removing residual noise using the artifact component as reference Deliverable

A fully functional Python-based application (ppg_gui) was developed, including:

  • Preprocessing module for signal cleaning and segmentation
  • Visualization interface for waveform inspection and analysis
  • Validation module based on Monte Carlo simulations to assess algorithm performance

Additional features:

  • Parallel processing for efficient handling of long-duration recordings
  • Quantitative evaluation using Relative Root Mean Square Error (RRMSE)
  • Deployment as a standalone executable (.exe), requiring no Python environment

My role

I was responsible for the end-to-end implementation of the signal processing pipeline and software development, including:

  • Translating the methodology from literature (Peng et al., 2014) into a working computational framework
  • Designing and implementing the cICA and LMS-based artifact removal pipeline
  • Developing the Python GUI application, integrating preprocessing, visualization, and validation modules
  • Implementing performance evaluation metrics and simulation-based validation
  • Optimizing the system for long-duration physiological recordings

Media